Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
China Pharmacist ; (12): 758-760,761, 2016.
Article in Chinese | WPRIM | ID: wpr-603816

ABSTRACT

Objective:To establish the method for the determination of emodin and danshensu Pinggan oral liquid. Methods:The contents were determined by HPLC. The chromatographic conditions for emodin were as follows: an Agilent Eclipse XDB-C18 column (150 mm × 4. 6 mm, 5μm) was used and the mobile phase was methanol-water (80 ∶20). The detection wavelength was 287 nm and the flow rate was 1. 0 ml·min-1 . The column temperature was 25℃ and the injection volume was 20 μl. The chromatographic condi-tions for Danshensu were as follows:an Agilent Eclipse SB-C18 column (150 mm × 4. 6 mm, 5 μm) was used and the mobile phase was methanol-1% acetic acid solution (2 ∶98). The detection wavelength was 280 nm and the flow was 1. 0 ml·min-1. The column temperature was 30℃ and the injection volume was 20 μl. Results:Emodin had a good linear relationship within the range of 26. 75-428. 00 μg·ml-1(r=0. 999 9). The average recovery was 102. 7% and RSD was 0. 76% (n=6). Sodium Danshensu had a good linear relationship within the range of 10.17-162.77 μg·ml-1(r =0.999 9). The average recovery was 100.5% and RSD was 1. 47% (n=6). Conclusion:The method is simple, accurate and reproducible, which can be used for the quality control of the prep-aration.

2.
China Pharmacy ; (12): 2541-2543,2544, 2015.
Article in Chinese | WPRIM | ID: wpr-605116

ABSTRACT

OBJECTIVE:To establish the quality standard of Banlangen dispensing granules. METHODS:Thin layer chroma-tography(TLC)was used to identify Isatis indigotica,leucine and arginine,the items according to granules preparations and the ex-traction were detected. HPLC was conducted to determine the content of (R,S)-goitrin. The Shimadzu VP-ODS C18 column was used with the mobile phase of methanol-0.05% phosphoric acid (7∶93,V/V) at the flow rate of 1.0 ml/min. The detection wave-length was set at 245 nm,and the column temperature was room temperature. The sample size was 10 μl. RESULTS:TLC showed clear spots and good resolution. Particle size,moisture,dissolubility and microbial limit test were all conformed to the specifica-tion. The extraction limit was no less than 25.0%.(R,S)-goitrin showed a good linear relationship in the range of 1.565 9-50.109 8μg/ml(r=0.999 9,n=6). The average recovery was 99.25%(RSD=2.08%,n=9);the RSDs of precision,stability and repeatabili-ty tests were no more than 1.12%. The content of(R,S)-goitrin was initially determined as 0.35 mg/g. CONCLUSIONS:The estab-lished quality standard has increased content determination,and the control programs are more comprehensive and reasonable. It can be used for the quality control of Banlangen dispensing granules.

3.
International Journal of Traditional Chinese Medicine ; (6): 435-438, 2015.
Article in Chinese | WPRIM | ID: wpr-464133

ABSTRACT

Objective To establish the quality standard of common selfheal fruit-spike granules. Mehtods Rosmarinicacid in the granules were identified by TLC. The extractives were tested by the method for determination of water-soluble extractives. The contents of rosmarinicacid were determined by HPLC. Results TLC had obvious characteristics with the spots clear and well-separated. The extraction limit was no less than 10.0%. Rosmarinicacid showed a good linear relationship at 0.062 5~2.008 0 mg/ml (r=0.999 8,n=6) with average recovery of 99.50% (RSD=1.21%,n=9). The content limitation of rosmarinicacid was discussed as 10.0 mg per pack according to the experiment data.Conclusion The method is easy-operated and accurate which has a good specificity for the quality control of common selfheal fruit-spike granules.

4.
China Pharmacist ; (12): 2021-2023, 2014.
Article in Chinese | WPRIM | ID: wpr-458791

ABSTRACT

Objective:To establish the quality standard for Isatidis folium dispensing granules. Methods:Indigo and indirubin in the granules were identified by TLC. The extract content was determined by a hot dipping method for the determination of alcohol-solu-ble extract. The content of indirubin was determined by HPLC. Results:The spots in TLC were clear and well-separated. The extrac-tion limit no less than 12. 0% was preliminarily drawn up. Indirubin showed a good linear relationship within the range of 0. 50-8. 04μg·ml-1(r=0. 999 9) with the average recovery of 99. 41%(RSD=1. 21%, n=9). The content limit no less than 50. 0 μg per pack was preliminarily drawn up for indirubin. Conclusion: The method is easy-operated and accurate with good specificity for the quality control of Isatidis folium dispensing granules.

SELECTION OF CITATIONS
SEARCH DETAIL